<LOGO>
FM Transmitter Measurement Report
Created: 2024-06-05 03-17-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 49 dBuV R-PCE
Pilot RDS Phase Difference
6.0 kHz 3.1 kHz -88 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
15 kHz 41 kHz 18912 0,2274
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,2 dBr -0,81 dBr -0,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 3:17, 5.06.2024
RT
"Ceske pisnicky ktere si zazpivate "
AF EON
88.9, 93.7, 98.6, 101.0, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 41 kHz MIN: 15 kHz % above 77 kHz: 0,2274 Acquired: 2024/06/05 3:17:44 Total samples: 18912 Equivalent time: 0:15:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: -0,5 dBr MIN: -1,2 dBr AVE: -0,81 dBr % above 0,2 dBr: 0,0 Last value: -0,7 dBr (2024/06/05 3:17:43) 03:04 03:06 03:08 03:10 03:12 03:14 03:16 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality